Fm 200 system installation manual

A typical case of protecting a power station using the fm 200 total suppression system is the basis for the following design information. The clean agent fire extinguishing system shall consist of fm200, agent cylinders, 1800. Installation manual this product meets and exceeds the requirements of ul 325, the standard which regulates gate opener safety, as established and made effective march 1, 2000, by underwriters laboratories inc. Fm200 fire suppression system for fire protection incontrol. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing. The ads system shall be engineered for total flooding of the hazard being protected. Installing an fm200 fire suppression system benefits of. The work described in the specification consists of all labor, materials, equipment, and services necessary and required to complete and test the system. Two 2 copies of the kidde ads fm200 fire suppression system, operation and maintenance manual shall be submitted after complete installation.

It shall not be used as a substitute in determining material and quantity requirements as defined in kidde fire systems design manuals and applicable nfpa standards. Context plus limited, fe227fm200 dupont, and chemori 227 chemori americas. Fm200 is a colorless, nontoxic gas perfectly suited to protect high value assets in areas that may be normally occupied, in locations where cleanup of other agents is problematic, when storage space for a fire suppression agent is. We install and service kidde fm200 fire suppression systems. Fm200 for mission critical equipment fire suppression. The system shall be capable of being actuated by manual discharge stations.

Once the fm200 fire suppression system discovers a fire in the room, the fm200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from. Fm200 dlp systems, warnings only arabic dry chemical ilp systems, warnings only arabic french language warnings. Fm200 total flooding fire suppression system data specification sheet general the fm200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. The system shall be a total flood fm200 suppression system supplied by pyrochem. System in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release. The fm200 is designed to be installed directly below the dispensing. The system shall provide a fm200 minimum design concentration of 7. United states coast guard approved cylinders that utilize fm200 suppression technology. Maintenance manual for the clean agent fire extinguishing system employing fm200 shall be submitted after complete installation. Wet chemical system installation manual autronica fire and security as division maritime spikkestad page 41 of 41. We specialize in the design of fm200, co2, foam, and water based fire protection systems as well as alarm and detection. By installing an fm200 fire suppression system, you are protecting your assets and employees with one of the leading waterless fire protection systems available.

Fg models feature lightweight, compact corrosion resistant aluminum cylinders for easy fit and installation. Chemical fm 200 fire suppression system of 120l type cylinder. Position the fm200 on the wall below the dispenser pumpstand with the water inlet and flush discharge fittings on the desired end. The connection kit hri200 and your pc can be connected with a usb cable. Fm200 clean agent fire suppression system hfc227 fike. Power the device from the pc through the usb connection. Fm 200 installation manual 3 fm 200 wiring the fm 200 polycarbonate housing comes with 10 pg knockout conduit holes in the housing. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Nfpa 2001, clean agent fire extinguishing system, is the governing code for designing the system, and nfpa 72, national fire alarm code, is followed for fixing the fire alarm system, an.

For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is. Carbon dioxide co2 clean agent fire suppression system. Fm200 is a waterless fire protection system, it is discharged into the risk. Autronica fire and security as division maritime industriveien 7, 3430 spikkestad, norway phone. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. All work shall be completed in a high degree of workmanship and in. Trim components trim components complete the installation of the fm200 system and consist of the electric valve actuator and the manual valve actuator. Many fire suppression systems can damage or destroy the very equipment theyre meant. The ansul fm200 fire suppression system protects what matters most. Utilizing the industry recognized fm200 suppression agent, amerex has.

Acoma drive, suite 106 scottsdale, az 85260 usa telephone. Many businesses install this system to protect their companys most important assets from a fire emergency, but the fm200 system isnt a system you can install and forget about. About this manual this manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system. Cylinders are automatic and manualautomatic, are corrosion resistant, lightweight, and fit most marine vessel engine compartments. Total number of fm200 cylinder this calculation tool is intended for use in developing approximate estimates of the material and equipment budgeting purposes. The fm200 system stops fires fast by deploying quickly to prevent extensive damage, excessive repair costs, and delayed downtime for your business. Janus fire systems is a full service fire protection company formed of professionals experienced in special hazard and industrial fire protection. Electrical installation simply requires connecting a plug connector to the underside of the pumpstand. Bosch security conventional fire panel 500 series basics of fire detection duration.

This manual is an integral part of the system and must be kept in its immediate vicinity at all times. Vsh200 clean agent fire suppression system hfc227ea. Download instructions for design, installation, operation, and maintenance. Do you have an fm200 fire suppression system installed in your houston area building. The fm200 fire suppression system contains sensitive detectors that can detect even the smallest fires. Service for fm200 systems western states fire protection can help to design, install, and provide ongoing service for your fm200 system.